New Gas Struts Won’t Compress? Here’s Why and How to Fix Them

Just installed new gas struts but they won’t compress?

Don’t worry. This is a common issue and usually does not mean the gas springs are defective.

Many users experience the same problems after installing heavy-duty lift supports:

  • The gas struts feel extremely stiff.
  • The piston rod cannot be pushed in by hand.
  • The lid stays open and will not close.
  • The gas springs feel much stronger than expected.

In most cases, there are two possible reasons:

  1. The gas struts have too much force for your application.
  2. The mounting position creates excessive lifting leverage.

Before replacing your gas struts, try adjusting the installation position first. A small change can often solve the problem.

This guide explains why new gas struts won’t compress and how to fix the issue.

Why Won’t My New Gas Struts Compress?

1. The Gas Struts Are Too Strong

Gas struts are rated by Newtons (N). A higher N rating means more lifting force.

For example, a 300N gas strut provides strong support for heavy lids and panels. However, if your lid is lighter than expected, the weight of the lid may not be enough to compress the gas spring during closing.

This can cause:

  • The lid cannot close properly.
  • The gas struts feel impossible to compress.
  • The lift supports push upward continuously.
  • The user thinks the gas struts are defective.

Actually, the gas springs may be working correctly — they may simply be stronger than your application requires.

2. Incorrect Gas Strut Mounting Position

The force rating is not the only factor affecting performance.

The installation position also changes how much force the gas strut applies.

A more vertical installation provides stronger lifting assistance.

A more horizontal installation reduces the effective lifting force and makes closing easier.

Therefore, adjusting the mounting location can often solve a “gas struts won’t close” problem without replacing the parts.

How To Fix Gas Struts That Won’t Compress

There are two solutions:

Solution 1: Adjust the Gas Strut Mounting Position

Solution 2: Replace With Gas Struts That Have the Correct Force Rating

We recommend trying adjustment first.

Solution 1: Adjust the Gas Strut Mounting Position

If the gas struts are too strong:

Move the upper mounting point closer to the hinge.

This creates a more horizontal installation angle and reduces closing resistance.

If the gas struts are too weak:

Move the upper mounting point farther away from the hinge.

This increases lifting assistance.

However, always make sure:

The gas strut can fully compress when the lid is closed.

The distance between mounting points must be greater than the compressed length of the gas spring.

how-to-adjust-gas-struts-installing position or mounting points

Advanced Example: Adjusting a 300N Gas Strut Installation

To understand how mounting position affects gas strut performance, let’s look at a real example.

Application:

  • Lid length: 25 inches
  • Lid weight: 45 lb (approximately 200N)
  • Gas struts: Two 15-inch lift supports
  • Force rating: 300N each
  • Compressed length: 9.1 inches

A pair of 300N gas struts provides strong lifting assistance. However, if the required force is lower, the lid may become difficult to close.

Step 1: Identify the Installation Points

The following points are used to analyze the installation:

  • A: Upper mounting point
  • B: Hinge reference point
  • C: Lower mounting point
  • A1: Position of A when the lid is closed
  • C1: Assumed location of the lower mounting point in the closed position
  • d: Compressed length of the gas strut

Measurements:

  • a: Distance from hinge to upper mounting point
  • b: Distance between A1 and C
  • c: Distance from B to lower mounting point
  • d: Gas strut fully retracted length (9.1 in)
Gas springs mounting point and installation guide, for apexstone 300N lift support gas struts

A common starting position is placing the upper mounting point approximately one-third of the lid length from the hinge.

For a 25-inch lid:

a = 25 × 1/3 ≈ 8.3 inches

This is only a starting point. The final position depends on:

  • Lid weight
  • Gas strut force
  • Opening angle
  • Available installation space

Step 2: Check the Closed Position

After selecting the mounting points:

  1. Open the lid to the desired angle.
  2. Install the lower bracket.
  3. Close the lid and check the distance between A1 and C.

The distance must be greater than the compressed length of the gas strut.

Example:

Compressed length:

9.1 inches

Therefore:

A1C must be greater than 9.1 inches.

Step 3: Calculate Required Gas Strut Force

The required force can be estimated using:

F = G × y / (c × 2)

Where:

  • F = required gas strut force
  • G = lid weight
  • y = half of lid length
  • c = distance from hinge reference point to lower mounting point

For this example:

  • G = 200N
  • y = 12.5 inches
  • c = 5 inches

Calculation:

F = (200 × 12.5) / (5 × 2)

F = 250N

The result shows that approximately:

250N per gas strut

is required.

However, the selected gas struts provide:

300N each

The additional force may cause the lid to resist closing.

Step 4: Adjust the Mounting Position

To reduce the closing force, move the upper mounting point closer to the hinge.

Original position:

a = 8.3 inches

Adjusted position:

a = 6.25 inches

This creates a more horizontal installation angle.

The important lesson:

The correct mounting position is just as important as choosing the correct gas strut force.

Solution 2: Replace Gas Struts With Correct Force Rating

If adjusting the mounting position does not solve the problem, the gas struts may simply have too much force.

In this case, replacing them with the correct Newton rating is the best solution.

When selecting replacement gas struts, consider:

  • Lid weight
  • Lid size
  • Existing gas spring length
  • Mounting location
  • Required lifting assistance

A properly selected gas spring should help movement — not fight against it.

Frequently Asked Questions

Can I compress a gas strut by hand?

No.

High-pressure gas struts are not designed to be compressed manually.

A 300N gas spring can require significant force. If it feels impossible to compress by hand, it does not necessarily mean the product is defective.

Why are my new gas struts too strong?

The most common reasons are:

  1. The force rating is too high.
  2. The mounting position creates too much leverage.
  3. The lid is lighter than expected.

How do I make gas struts easier to close?

Try moving the upper mounting point closer to the hinge.

This creates a more horizontal angle and reduces closing resistance.

If adjustment does not help, choose a lower-force gas spring.

Should gas struts be installed rod down?

In many applications, installing gas struts rod-down helps lubricate the internal seal and may improve service life.

Always follow the installation requirements for your specific application.

Conclusion

New gas struts that won’t compress are usually caused by incorrect force selection or an unsuitable mounting position.

Before replacing your lift supports, try adjusting the mounting points first.

A small installation change can make a significant difference.

Need help choosing the right gas struts?

Check our gas spring sizing guide or contact us with your lid weight, dimensions, and current gas spring specifications. We’ll help you find the right solution.